Are fire extinguishers sufficient and easily accessible?

Sufficient fire extinguishing equipment Fire extinguishers should be installed no lower than 1 meter from the working ground, but no higher than 1.4 meters. Fire extinguishers should not weigh more than 11.3 kg. In areas with flammable liquids, the distance between fire extinguishers should not exceed 15 meters. In areas without flammable liquids, such as offices, the distance between fire extinguishers should not exceed 23 meters. Fire extinguishers are suitable for specific materials. Dry powder fire extinguishers - for most occasions. Halon fire extinguishers - for expensive electrical equipment. Water-type fire extinguishers - Class A fire (ordinary burning materials).
Carbon dioxide type fire extinguishers - Class B and C fires (fires caused by flammable liquids and electrical appliances)

Inspection of fire-fighting equipment. Check and estimate weight. Check latches and seals. Weigh carbon dioxide fire extinguishers every 6 months. Have portable fire extinguishers been refilled within a year?
Are any portable fire extinguishers damaged, unusable or lost?
Are emergency evacuation drills conducted and recorded for each shift each year (including dormitories)?
In places where the staff turnover is greater than 30%, emergency evacuation drills should be conducted twice a year. In places without fire sprinkler systems, all employees should be evacuated within 5 minutes, while in places with fire sprinkler systems, the time can be extended to 10 minutes. Does the factory have a fire alarm system installed?
Fire alarms can be heard throughout the plant. Fire alarms must be installed in plant buildings and dormitories. The system can be manually operated. Are emergency exits evenly distributed and readily accessible? Are they unobstructed and at least 91 cm (36 in) wide?
Emergency exits are unobstructed. No objects should be stored against or under the fire door at any time. Are the labels on the emergency exit doors visible from 31 meters (100 feet)?
Are the emergency exits of the factory and dormitories locked?
Emergency exit doors cannot be locked with locks, clasps, chains, bolts or other locking devices. Emergency exit doors can be easily opened from the direction of escape, and no special knowledge or skills are required.

<<:  Tchibo Company Profile-Tchibo Factory Inspection Consulting

>>:  Mattel Factory Inspection/Inspection Consultation Workplace Safety

Recommend

Plume Design—Smart Home Services Company

What is PlumeDesign? Plume Design is a smart home...

What is Filemail? What are the features of Filemail?

What is Filemail? Filemail is a small company fou...

Landingcube: How to promote off-site on Amazon?

Landingcube is a tool similar to AMZPromoter. It ...

Differences between TS16949 4th edition certification rules and 3rd edition

The fourth edition of the latest TS16949 certific...

Why do traders also need GRS certification?

After the GRS recycling certification was obtaine...

What is a C2C platform? What is its profit model?

What is C2C platform? C2C is also called CTC, whe...

Purpose of FSC forest certification audit

What is the purpose of FSC forest certification a...

GRS (Global Recycle Standard) Global Recycling Standard

The Global Recycling Standard GRS certification is...

What is SCS Kingfisher Certification?

What is SCS? SCS Global Services, referred to as ...

What sites does AMZHelper support? What services does AMZHelper provide?

What sites does AMZHelper support? AMZHelper supp...

ICTI factory audit work time management procedures

1. Purpose To formulate policies and procedures t...

What is Tinkleo? What services does Tinkleo provide?

What is Tinkleo? Tinkleo is an export B2C integra...

Features of GOST-R certificate, which is valid for one year

What are the characteristics of a GOST-R certific...